ND9 Indicator Light
Green items may be substituted with blue, and red items with yellow, subject to stock availability.
1. General
1.1 Electric ratings: 230V, AC50/60Hz.
1.2 Rated insulation voltage Ui: 500V.
1.3 Protection grade: IP20
1.4 Rated operational current: ≤20mA
1.5 Life: LED≥30000h.
1.6 Standard: IEC/EN 60947-5-1
2. Operating Conditions
2.1 The ambient temperature ranges from -5°C to +40°C, with the average temperature not exceeding +35°C in any 24-hour period.
2.2 Altitude: ≤ 2000m.
2.3 Air conditions at the mounting site should ensure that relative humidity does not exceed 50% at the maximum temperature of +40°C. Higher relative humidity is permissible at lower temperatures; for instance, RH can be 90% at +20°C. Special measures must be implemented to prevent the occurrence of dew.
2.4 Mounting category: Ⅱ, Ⅲ.
2.5 Pollution grade: Ⅱ.
2.6 Mounting mode: Use the TH35-7.5 standard rail, ensuring the angle between the mounting and the vertical plane does not exceed 5°.
3. Wiring
2 The cross-sectional area of the conductor is 1.0 mm², and the tightening torque should be 0.8 N•m.